FAR-2xx7 : Radar Shut Down

Includes : FAR-2117 FAR2117 FAR-2817 FAR2817 FAR-2127 FAR2127 FAR-2827 FAR2827 FAR-2837S FAR2837S X-BAND XBAND S-BAND SBAND

Written by Ian Upham

Updated at October 22nd, 2021

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Latest News
  • Products
    Radar ECDIS VDR TimeZero NavNet TZT NavNet MFD Chart Plotter GPS AIS Communication Echo Sounder Sonar Fish Finder Multi Beam Sonar Current Indicator Compass Autopilot Speed Log BNWAS Instruments Monitors & Displays Envision AR System Power Supply Unit Interfaces
  • Type Approval Certs
+ More

Please follow the below steps to assist with diagnosing the cause of your FAR-2xx7 Radar Shut Down issue

Decision Tree
Please check external power supply. 

220 VAC / 100 VAC / 24 VDC

  • Voltage OK
  • Voltage NG
  • Add Button
Please check RPU-130 Fuse.

Does Radar now Power on?

  • Yes
  • No
  • Add Button


If you found this Guide helpful, please click the Thumbs up button below so we know to make more like this. 

Please carry out the following steps : 

1) Isolate Radar from External Power Supply. Please ensure the system is safe to work on before proceeding with the next steps. 

If any doubts, please stop and contact your local Furuno Agent.

2) Open RPU-013. Remove 4 x screws holding top cover in place. Slide cover off RPU. 

You can now open the Processor door to expose the power connections.

3) Locate the HV PCB in the top right hand corner of the exposed area. 

Please disconnect the HV Output (Single Brown Cable). 

This connection is shown in the below image highlighted in RED.

4) Close the RPU-013 and make safe.

5) Restore external power supply to the RPU-013

Does the Radar now Power On? 

  • Yes
  • No
  • Add Button
If the Radar now Powers on with the HV Output disconnected it would suggest an issue with the Antenna Transmission Circuit.

Please leave the HV Output disconnected and arrange a service attendance with a trained/experienced engineer.
 
Most Common Parts Likely to be needed for a fault of this kind : 
  • 03P9244 MD PCB (Check which particular Type is needed based on Radar Type 12kw/25kw/35kw)
  • Magnetron 
  • 03P9017 HV PCB (Just in case)


Please carry out the following steps : 

1) Isolate Radar from External Power Supply. Please ensure the system is safe to work on before proceeding with the next steps. 

If any doubts, please stop and contact your local Furuno Agent.

2) Re-Open RPU-013 as per the previous check.

3) Locate the HV PCB in the top right hand corner of the exposed area. 

Please disconnect the HV Input supply. 

This connection is shown in the below image highlighted in RED.

4) Close the RPU-013 and make safe.

5) Restore external power supply to the RPU-013

Does the Radar now Power On? 

  • Yes
  • No
  • Add Button
If the Radar now Powers on with the HV Input disconnected it would suggest an issue with the HV PCB.

Please leave the HV Input disconnected and arrange a service attendance with a trained/experienced engineer.
 
Most Common Parts Likely to be needed for a fault of this kind : 
  • 03P9017 HV PCB (A Type if 12kw version / B Type if 25kw/35kw version)

The issue may be more involved, however this part will need to be replaced first.

If the Radar still does not powers on it would suggest an issue with the main PWR PCB.

Please isolate the system from external power and arrange a service attendance with a trained/experienced engineer.
 
Most Common Parts Likely to be needed for a fault of this kind : 
  • 03P9339 PWR PCB (Check which particular Type is needed based on External Power Supply AC or DC) 
  • 03P9017 HV PCB (Just in case)
Please investigate External Power Supply






Was this article helpful?

Yes
No
Give feedback about this article

How can we improve this article?

Share additional info and suggestions

Related Articles

  • Magnetron Lead Wire Change
Portsmouth
West Building
Penner Road
Havant, Hampshire
PO9 1QY

Tel: 02392 441000
Email: sales@furuno.co.uk
Fraserburgh
South Breakwater
Fraserburgh
Aberdeenshire
AB43 9TD

Tel: 01346 518300
Email: sales@furuno.co.uk
> Furuno International
> Navnet Brochure
> General Brochure


> Privacy Policy
FacebookInstagramLinkedinYoutube
© 2021 Copyright © FURUNO (UK) LTD. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Definition by Author

0
0
Expand